AUTOMATIC CATHODIC PROTECTION RECTIFIER

APPLICATION:

  • Metallic and reinforced concrete structures even located in the zone of dynamic stray currents
  • Forced drainage of stray currents

MEASURING AND MONITORING PARAMETERS:

The rectifier is equipped with measuring and telecommunications block (device TE-RCU/SCR) and ER probe for verification of the following parameters:

  • Value of output voltage and current from the CP rectifier station – Uout, Iout
  • Intensity of DC current across a coupon /soil surface – Idc
  • Intensity of AC current across a coupon/soil surface - Iac
  • Drainage current intensity - Ip
  • ON/OFF potential of steel structure vs the reference electrode Cu/CuSO4 - Eon, Eoff,
  • Value of the alternating voltage v.s. earth- Uac
  • Corrosion rate - Vcorr
  • Density of DC current across a coupon /soil surface - Jdc
  • Density of AC current across a coupon/soil surface - Jac
  • Power supply status
  • Door position: open/closed
  • Alarming notifications for all measuring values in case that measuring varies from the set limits
  • Alarming notifications informing about the energy supply interruption and the open door

CONTROL AND COMMUNICATION:

  • Remote: GSM/GPRS; MODBUS
  • Manual: USB port for PC/lap top or via keyboard

TECHNICAL CHARACTERISTICS:

  • Power supply: 220V;
  • Range: Uizl (0-50V), Iizl(0-40A), Idc(0-20A), Iac (0-5A), Ip (0-100A), Uac (0-50V),
    Vcorr(0-20000μm/god), Jdc (0-10000A/m2), Jac (0-10000A/m2); Uc =(-5000; 0mV);
  • Connections: AC power supply, anodes, a protected structure, rail, reference electrode, ER probe, earthing;
  • Enclosure: stainless steel / steel / aluminum / Polyester / IP43-IP66 / Ex